Title Hydrostratigraphic Profiling Tool and Pneumatic Slug Test Investigates of the Hydraulic Conductivity for Shallow Aquifers
Date of Defense 2009-07-09
Page Count 129
Keyword
  • direct push
  • hydrostratigrapic profiling tool
  • pneumatic slug tester
  • Abstract The hydrostratigrapic profiling tool (HPT) and the pneumatic slug tester (PST) are two state-of-the-art technologies for real-time and in-situ determination available for shallow (less than 30 meters) of K(z), unconsolidated materials of grain size smaller than about 4mm. In Taiwan groundwater monitoring network to obtain hydraulic conductivity information for deep of K. How to effectively and rapidly determine K(z) is an important issue in the design and conduction of aquifer recharge. Because they are attached to the direct-push machine, their application requires no well installation and is relatively rapid. In this study include (1) HPT and PST equipment, limiting and data analysis methods, (2) HPT and PST tests at three sites in Southern Taiwan, collecting the vertical variation of electric conductivity and formation response pressure, and depth-specific hydraulic conductivity; regression analysis of them yields K(z) of the test locations, and (3) a chart for electric conductivity of different unconsolidated materials and grain size by making use of literature data and field data collected in this project, and it provides reference for HPT data analysis. The results of this assessment demonstrate that the HPT and PST can provide high-resolution K estimates.
    Table of Content 摘要i
    Abstractii
    目錄iii
    圖目錄v
    表目錄xi
    第一章 緒論1
    1.1 研究目的2
    1.2 研究方法3
    第二章 水文地層剖析儀與氣壓式微水試驗儀工作程序8
    2.1 概要8
    2.2 適用範圍及限制10
    2.3 HPT試驗步驟11
    2.4 PST試驗步驟14
    2.5 資料分析方法17
    2.5.1 HPT資料分析17
    2.5.2 PST資料分析20
    2.5.2.1 PST反應特徵:20
    2.5.2.2形狀因子(shape factor):20
    2.5.2.3振盪反應資料分析:23
    2.5.2.4非振盪反應分析:25
    第三章 實例分析26
    3.1高雄縣潮寮國小28
    3.2屏東縣大明國小40
    3.3高雄縣昭明國小52
    3.4案例討論56
    第四章 HPT與PST國內外研究成果討論63
    4.1 導電度、地質材料與粒徑大小關係80
    第五章 結論與建議83
    參考文獻85
    附錄A、HPT試驗設備介紹89
    附錄B、PST試驗設備介紹95
    附錄C、HPT儀表顯示器介紹及操作說明102
    Reference Butler, J.J. Jr. 1998, The Design, Performance, and Analysis of Slug Tests, Boca Raton, Florida: Lewis Publishers.
    Grant, F.S., and G.F. West, 1965, Interpretation Theory in Applied Geophysics. US: McGraw-Hill Inc.
    Sumner, J.S., 1976, Principles of Induced Polarization for Geophysical Exploration. New York: Elesvier.
    Vennard, J.K., and R.L. Street, 1975, Elementary Fluid Mechanics,5th ed. New York: John Wiley and Sons.
    Wentworth, E. C., The Valley of Enna & Other Poems of 1922: The Growing Dawn, and Spirit of the Lower North Side; Plays of 1922, Chicago, Covici-McGee.
    Bouwer, H. and Rice, R. C. 1976, A slug test for determining hydraulic conductivity of unconfined aquifer with completely or partially penetrating wells, Water Resour. Res. 12, no. 3: 423-428.
    Butler, J.J., Jr., J.M. Healey, L. Zheng, W. McCall, and M.K. Schulmeister, 1999, Hydrostratigraphic characterization of unconsolidated alluvium with direct-push sensor technology , Kansas Geological Survey Open-File Report 1999-40.
    Butler, J.J. Jr., A.A. Lanier, J.M. Healey, and S.M. Sellwood, 2000, Direct-Push Hydraulic Profiling in an Unconsolidated Alluvial Aquifer, Kansas Geological Survey Open-File Report 2000-62.
    Butler, J.J. Jr. 2002, A simple correction for slug tests in small diameter wells, Ground Water 40, no.3: 303-307.
    Butler, J.J. Jr., J.M. Healey, G.W. McCall, E.J. Garnett, and S.P. Loheide II, 2002, Hydraulic Tests with Direct-Push Equipment, Ground Water 40, no. 1: 25-36.
    Butler, J.J. Jr., E.J. Garnett, and J.M. Healey, 2003, Analysis of slug tests in formations of high hydraulic conductivity, Ground Water 41, no. 5: 620-630.
    Butler, J.J. Jr., P. Dietrich, V. Wittig, and T. Christy, 2007, Characterizing Hydraulic Conductivity with the Direct-Push Permeameter, Ground Water 45, no. 4: 409-419.
    Chen, C. S., and Wu, C. R., 2006, Analysis of Depth-Dependent Pressure Head of Slug Tests in Highly Permeable Aquifers, Ground Water 44, no. 3: 472-477.
    Chen, C. S., 2006, An Analytic Data Analysis Method for Oscillatory Slug Tests, Ground Water 44, no. 4: 604-608.
    Chen, C. S., 2008, An analytical method of analyzing the oscillatory pressure head measured at any depth in a well casing, Hydrological Process 22, no. 8: 1119 -1124.
    Dietrich, P., and C. Leven, 2006, Direct push technologies, In Groundwater Geophysics, ed. R. Kirsch, 321–340. Berlin, Heidelberg, Germany: Springer.
    Dietrich, P., J.J. Butler Jr., K. Faiss, 2008, A rapid method for hydraulic profiling in unconsolidated formations, Ground Water 46, no. 2: 323-328.
    Geoprobe, 2007, HPT Standard Operating Procedure Technical Bulletin no. MK3137. 1-20.
    Healey, J.M., J.J. Butler Jr. and D.O. Whittemore. 2001, Steam-aquifer interaction investigations on the middle Arkansas River: Construction of groundwater observation wells in Edwards, Pawnee, and Barton County, Kansas. Kansas Geological Survey Open-File Report 2001-48.
    Healey, J.M., and S.M. Sellwood, 2004, The KGS Direct-Push Hydrostratigraphic Profiling Tool, Kansas Geological Survey Open-File Report 2004-44.
    Hvorslev, M. J., Time lag and soil permeability in ground-water observations, U.S. Army Corps of Engrs. Waterways Exper. Sta. Bull, no. 36, 1951.
    Jong, S.C., J.T. Wilson, and F.P. Beck Jr., Measuring Vertical Profiles of Hydraulic Conductivity with in situ Direct-Push Methods, 2000, Journal of Environmental Engineering, 775-777.
    McCall, W., J.J. Butler Jr., J.M. Healey, A.A. Lanier, S.M.Sellwood, and E.J. Garnett. 2002, A dual-tube direct-pushmethod for vertical profiling of hydraulic conductivity inunconsolidated formations, Environmental and EngineeringGeoscience 8, no. 2: 75–84.
    Schulmeister, M.K., J.J. Butler Jr., J.M. Healey, L. Zheng, D.A. Wysocki, and G.W. McCall, 2003, Direct-push electrical conductivity logging for high-resolution hydrostratigraphic characterization, Ground Water Monitoring and Remediation 23, no. 3: 52-62.
    Sellwood, S.M., J.M. Healey, S. Birk, and J.J. Butler Jr., 2005, Direct-Push Hydrostratigraphic Profiling: Coupling electrical logging and slug tests, Ground Water 43, no. 1: 19-29.
    van der Kamp, G. 1976, Determining aquifertransmissivity by means of well response test: The underdamped case, Water Resour. Res. 12, no. 1: 71-77.
    Zlotnik, V.A.,M. Burbach, J. Swinhart, D. Bennett, S.C. Fritz, D.B. Loope, and F. Olaguera, 2007, Using Direct-Push Methods for Aquifer Characterization in Dune-Lake Environments of the Nebraska Sand Hills, Environmental & Engineering Geoscience, vol. XIII, no. 3: 205-216.
    秦啟文,鄭立新,林文勝,楊舜行,2000年,屏東平原地下水資源之研究。
    陳汝勤,莊文星,1991年,岩石學,第176頁。
    羅俊雄,溫國樑, 陳銘鴻, 謝宏灝,2002年,全國強震測站場址工程地質資料庫之建立。
    Advisor
  • Chia-shiun Chen(陳家洵)
  • Files
  • 956204009.pdf
  • approve immediately
    Date of Submission 2009-07-17

    [Back to Results | New Search]


    Browse | Search All Available ETDs

    If you have dissertation-related questions, please contact with the NCU library extension service section.
    Our service phone is (03)422-7151 Ext. 57407,E-mail is also welcomed.